Act now:SCKit. MSPs and IT teams running on-premises ScreenConnect with Labtech Plus, RMM Plus, RMM+ or the Password Link extensions installed, and anyone whose technician clients are older than 26.6.5.
Patch this week:Apache httpd 2.4.71 Fixes Critical mod_http2 RCE. Anyone running Apache HTTP Server 2.4.55 through 2.4.70 with h2 or h2c in a Protocols directive, especially on internet-facing hosts and in container images built before November 11, 2026.
None of it touches your stack? Then there is nothing to do today. That is a result, not a failure to read carefully.
Apache rates this critical and it needs no authentication, but it only applies when HTTP/2 is enabled, there is no public exploit, and switching to HTTP/1.1 removes the exposure until you can upgrade.
Must act: Anyone running Apache HTTP Server 2.4.55 through 2.4.70 with h2 or h2c in a Protocols directive, especially on internet-facing hosts and in container images built before November 11, 2026.
Can relax: Servers that only speak HTTP/1.1, servers on 2.4.54 or earlier, and RHEL 8 and earlier, which Red Hat lists as not affected.
Check the version with httpd -v or apachectl -v; 2.4.55 through 2.4.70 is in range.
Check whether HTTP/2 is on: apachectl -M | grep http2, then search the configuration for Protocols lines that list h2 or h2c, including per virtual host.
Upgrade to Apache HTTP Server 2.4.71 or your distribution's fixed package and restart.
If your ScreenConnect server has an RMM+ family extension installed, disable it now and hunt for rogue clients; attacks on on-premises servers were still being seen on November 16.
Must act: MSPs and IT teams running on-premises ScreenConnect with Labtech Plus, RMM Plus, RMM+ or the Password Link extensions installed, and anyone whose technician clients are older than 26.6.5.
Can relax: ScreenConnect users who never installed an RMM+ family extension and whose technician clients run 26.6.5 or later; the CVE record says the ScreenConnect server and client are not affected by the extension flaw.
On on-premises ScreenConnect, disable Labtech Plus, RMM Plus, RMM+, RMM Plus Password Link and RMM+ Password Link, and do not re-enable or reinstall them until ConnectWise says so.
Update the on-premises server to the latest supported version and confirm every technician client runs 26.6.5 or later.
Review Run Command and Toolbox history for mass actions nobody started, and look for a second ScreenConnect client on endpoints.